In เกจวัดไนโตรเจนราคา from chemistry laboratories to industrial facilities, to be able to ensure the security of life and property towards a attainable fireplace hazard, extinguishing systems are used in addition to detection and alarm systems. It can additionally be extraordinarily important that the extinguishing systems put in could be triggered by the fire extinguishing management panel, to find a way to remove a potential fire with early intervention.
In order to fulfill these needs, and with 35 years of sectoral data and expertise, Mavili Elektronik presents:
Maxlogic Conventional Fire Extinguishing Control Panel working in accordance with the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which permits the remote performance of the indicators and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing process to be started manually and remotely; and
to ensure that the extinguishing process may be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced using surface-mount expertise and are aimed toward making the automation of the extinguishing system and fire and gasoline detection system good.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by at all times contemplating the wants of the set up. In circumstances that require the mixing of the extinguishing system with the clever addressable hearth detection system, it provides solutions through the monitoring modules that even have a ‘supervised’ possibility.
Supervised monitoring modules play an important position in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or quick circuit within the wiring between the contact monitoring modules and the peripheral systems could cause disruption of the triggering, with probably important consequences. For this purpose, when selecting monitoring modules, it ought to be taken into account that they have supervised options.
Image copyright: Mavili
Since Maxlogic intelligent addressable hearth detection and alarm management panels are continuously communicating with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to observe situations corresponding to open circuits and short circuits that may happen in the system. Many duties could be performed in the hearth extinguishing installation, such as the control and monitoring of all valves that may interrupt the circulate of water, water circulate alarm switches, pressure switch, and electric or diesel hearth pumps.
By including two contact monitoring modules to two separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be used to manage errors and the other to control the fire state of affairs, monitoring and control of the extinguishing system via an clever addressable fireplace detection and alarm system can be carried out effectively.
For extra info, go to www.mavili.com.tr/en